Highlights
- KIC 200/ KIC 300 facilitates the development of a trolley bus with IMC® technology based on a common battery bus platform
- DC/DC converter is designed for a wide range of input and output voltages
- Double insulation of vehicle and battery against the overhead power supply with optional insulation monitoring
- Reverse polarity protection for any polarity of the overhead power supply
- Integrated input filter and overvoltage protection according to EN 50124-2
- Compliance with EMC requirements according to UN / ECE R10 and EN 50121-3-2
- High power density and optimized design for roof mounting installation applications
Tasks
The galvanically isolating DC/DC converter KIC 200/ KIC 300 is primarily designed for IMC® (In-Motion Charging) buses: powered by overhead line, the KIC 200 works as a battery charger, allowing an e-bus to become an IMC® bus.
When powering by overhead line, the road vehicle needs double electrical isolation. The KIC 200/ KIC 300 meets this requirement and provides an interface to the common 800 V e-mobility equipment. With the help of our KIC 200/ KIC 300, e-buses, e-trucks and various specialty vehicles can be upgraded for operation and battery charging from the overhead line network with little effort.
The KIC 200/ KIC 300 is characterized by its high power density and optimized design for roof mounting.
Technical data for KIC 200
Input voltage range | DC 380 ... 1000 V |
---|---|
Maximum input current | 350 A |
Output voltage range | DC 500 ... 850 V |
Maximum output current | 310 A |
Maximum continuous power | 200 kW |
Control supply voltage | DC 24 V according to EN 50155 |
---|---|
Maximum current consumption | ≤ 33 A |
Digital I/O | 4 x DO / 4 x DI |
Service interface | Ethernet |
Communication interface | CANopen |
Dimensions (L x W x H) | 1643 mm x 877 mm x 378 mm |
---|---|
Weight | 265 kg |
Cooling | Forced air, -40 °C ... +45 °C |
Protection class | IP54 |
Device protection | Overvoltage protection according to EN 50124-2, OV3, Overcurrent protection, Temperature monitoring |
---|---|
Electromagnetic compatibility | EN 50121-3-2, UN ECE R10 |
Fire protection | EN 45545 |
Mechanical strength | UN ECE R100 |
Technical data for KIC 300
Input voltage range | DC 380 ... 1000 V |
---|---|
Maximum input current | 520 A |
Output voltage range | DC 500 ... 850 V |
Maximum output current | 460 A |
Maximum continuous power | 300 kW |
Control supply voltage | DC 24 V according to EN 50155 |
---|---|
Maximum current consumption | ≤ 63 A |
Digital I/O | 4 x DO / 4 x DI |
Service interface | Ethernet |
Communication interface | CANopen |
Dimensions (L x W x H) | 1643 mm x 1261 mm x 378 mm |
---|---|
Weight | 310kg |
Cooling | Forced air, -40 °C ... +45 °C |
Protection class | IP54 |
Device protection | Overvoltage protection according to EN 50124-2, OV3, Overcurrent protection, Temperature monitoring |
---|---|
Electromagnetic compatibility | EN 50121-3-2, UN ECE R10 |
Fire protection | EN 45545 |
Mechanical strength | UN ECE R100 |
Cable Connections
For electrical interfaces plug-in connectors are used: Harting connectors for DC 24 V / communication and Pfisterer connectors for HV power interface. Plug-in connectors enable pre-assembly of the cables and quick equipment installation on vehicle roof.
Mounting
To fulfill the double electrical insulation between the overhead line and the vehicle chassis, insulated installation of the KIC 200/ KIC 300 on the vehicle roof is required (insulators can be provided optionally). Air duct / cooling air must be transverse to the direction of travel according to the figure below.