- Direct supply from 750V mains
- Control of the compressor motor via V/f characteristic curve
- Ramp start-up
- Specially designed for integration into railway air conditioning systems
Technical Data
| Contact wire voltage | DC 400 ... 1070 V |
|---|---|
| 3AC output | 48 kVA, 3AC 400 V/ 23 kVA 3AC 230 V, 0…70 Hz |
| Communication | CAN, digitale I/Os |
|---|---|
| Control | DC 24 V |
| Dimensions (L x W x H) | 760 mm x 450 mm x 450 mm (depending on version) |
|---|---|
| Weight | 100 to 130 kg (incl. magnetic components) |
| Protection class | IP00 |
| Cooling | Forced air cooling (> 140 l/s) |
| Ambient temperature | -25 °C … +45 °C |
| Overvoltage protection, contact wire | EN 50124-2 |
|---|---|
| EMV | EN 50121-3-2 |
| Fire protection | EN 45545 |